close
Download our Mobile App for free With the instant messaging feature, Messaging is now live, start using it now!
All Menu

Please provide us with your offer for 2XNGR, based on the following information: Two Neutral grounding resistances, 3.3 kV, limiting current 300 Ampere, 10 seconds, and 6.35 Ohms. We have a project in Iraq and would like to receive your best offer.

We pleased to contact you and offer our interest to deal with you for earthing equipments. Looking forward to hearing from you soon for more discuss our needs.

Hello. I'm after earth backfilling compound, a match for Marconite for a UK client. Happy to buy FOB Turkish port, or ex-factory.

May you please provide the prices for the attached items attached. If possible by end of day today. Please see the attached requests for mechanical and electrical works.

I want to ask Do you have this ? You have ligthning rode and all thing about earthing What you have please ?

Please kindly recommend the top 3 manufacturers of medium voltage and high voltage switchgear 66 kV SWITCHGEAR HV system consists of: • Withdrawable circuit breaker pc 1 • Earthing switch pcs 2 • Voltage transformer pcs 3 • Current transformer pcs 3 • Surge arrester pc 3 • Joining material set 1 • Steel construction set 1 The 66 kV switchgear system is placed indoor, in a separate room. It comprises of a withdrawable live tank circuit breaker, including both breaking and disconnecting function, together with instrument transformers. 72,5kV THREE‐PHSE SF6 CIRCUIT BREAKER, 3P OPERATION Brief performance description: • Installation: Outdoor/Indoor • Type: Withdrawable, disconnecting function SF6 • Power frequency: 50 Hz • Rated voltage: 72,5 kV • Rated current: 2000 A • Rated breaking circuit: 25 kA • Operation type: 3pole 72,5kV SUBSTATION EARTH SWITCH Brief performance description: • Installation: Outdoor/Indoor • Power frequency: 50 Hz • Rated voltage: 72,5 kV • Rated current: 2000 A • Operating mechanism: Manual or motor Medium voltage switchgear panel used for connection of generators, generator synchronisation, power supply of station service system, voltage and current metering and connection to common step-up transformer outgoing for evacuation of generated power to grid. Equipment: Metal-enclosed, modular MV switchgear, for indoor installation, with routine tests, without type, factory-acceptance and special tests, made up of modular units with main characteristics listed below. Configuration • According to SLD Main technical data: • Nominal system voltage: 10 kV • Rated voltage: 24 kV@ 1000 m a.s.l. • short-duration power-frequency withstand voltage: 50/60 kV @ 1000 m a.s.l. Lightning impulse withstand voltage 125/145 kV @ 1000 m a.s.l. • Rated frequency: 50 Hz • Rated current, busbar: 630 A • Short-circuit withstand current: 25 kA (1 s) • Busbar insulation: AIS • Circuit breaker type: Vacuum, E2, M2 • Auxiliary voltage: DC 110 V, DC 24 V, AC 230 V • Installation Ind I would like communication by email

I'm looking for hot-dip galvanized earth strip 24*5 mm. Please share your best FOB quote. Thanks in advance.

Support Whatsapp Back to Top